dc.descriptionLa manipulación de productos químicos en los laboratorios docentes es habitual y necesaria sin importar el campo de estudio. Como principio preventivo, una vez se tiene que la exposición no se puede eliminar o disminuir, la implantación de medidas de protección colectiva (vitrinas de gases) es la acción preventiva primera. A una vitrina de laboratorio se le exige el arrastre del contaminante en cualquier operación de desprendimiento de gases o vapores. Haciendo uso de la Norma Europea EN 14175-4 se realizó un estudio de la metodología a seguir para realizar el análisis in situ y determinar la eficacia del sistema de extracción. Se han evaluado distintas vitrinas de gases de los laboratorios químicos de la Universidad de Alicante mediante la norma indicada. La metodología utilizada ha resultado adecuada para el estudio de los sistemas de extracción objeto de estudio. Se ha determinado la eficacia de aspiración que presentan los sistemas de extracción seleccionados para el uso de sustancias corrosivas y tóxicas, y para sustancias muy tóxicas. Se han presentado las propuestas de mejorar para los sistemas estudiados.es_ES
dc.description.abstractThe handling chemicals in teaching laboratories is common and necessary part regardless of the field of study. Exposure to chemicals is characterized by small and hardly reach the allowable limit value. As a precautionary principle, once you have that exposure can not be eliminated or decreased, the implementation of collective protection measures (fume) is the first preventive action. In a glass case you are required laboratory contaminant drag any operation off gases or vapors. Using the EN 14175-4 a study of the methodology to perform on-site analysis and determine the effectiveness of the extraction system was performed. Fume various chemical laboratories of the University of Alicante by the abovementioned rule were evaluated. The methodology has proved suitable for the study of extraction systems under study. Suction efficiency presenting systems selected for use of corrosive and toxic extraction was determined, and highly toxic substances. There have been proposals for improving the systems studied.es_ES
dc.language.isoeses_ES
dc.subjectSeguridad, Riesgos Laborales y Ergonomíaes_ES
dc.titleDETERMINACIÓN DE LA EFICACIA DE LAS VITRINAS DE GASES EN LABORATORIOS DOCENTESes_ES
dc.title.alternativeDETERMINATION OF THE EFFECTIVENESS OF FUME CUPBOARD ON TEACHING LABORATORIESes_ES