dc.descriptionUno de los principales problemas que se plantean actualmente durante la implantación de prótesis en el sistema musculo esquelético mediante procesos quirúrgicos es su estabilidad biomecánica. En el caso particular del conjunto prótesis-femur existe la necesidad de proponer modelos geométricos que permitan un análisis fiable sobre su funcionalidad mediante el empleo de Elementos Finitos. La presente comunicación propone la obtención de un modelo geométrico real de un conjunto prótesis-femur mediante técnicas de geometría computacional, lo que permite realizar una simulación posterior mediante Elementos Finitos de su comportamiento biomecánico bajo la acción de distintos regímenes de carga. El modelo generado ha sido validado mediante la acción de distintos regímenes de carga, constituyendo un modelo de gran utilidad para el médico ortopédico que le permite predecir la estabilidad biomecánica de la estructura acoplada prótesis-femur frente a los desplazamientos, los esfuerzos y las deformaciones que puede sufrir este tipo de implante.es_ES
dc.description.abstractOne of the main issues arising nowadays during the implantation of prosthesis in the musculoskeletal system by means of surgery-related procedures is its biomechanical stability. In the particular case of the prosthesis-femur set, there exist the need of proposing geometric models that permit a reliable analysis of its functionality by using finite elements. The present communication proposes to obtain an actual geometric model of a prosthesis-femur set by using computational geometry techniques, which permits to perform, by means of finite elements, a posterior simulation of its biomechanical behavior under the action of various load regime. The generated model has been validated with various load regime, becoming a model extremely useful for the orthopedic physician, providing the possibility of predicting the biomechanical stability of the prosthesis-femur set against the displacements, efforts and deformations that this kind of transplant can suffer.es_ES
dc.language.isoeses_ES
dc.subjectIngeniería de Producto, Procesos y Diseño Industriales_ES
dc.titleDISEÑO GEOMÉTRICO Y SIMULACIÓN DE FUNCIONALIDAD DE UNA PRÓTESIS DE CADERA EN EL SISTEMA MUSCULO-ESQUELÉTICO DEL CUERPO HUMANOes_ES
dc.title.alternativeGEOMETRIC DESIGN AND FUNCTIONAL SIMULATION OF A HIP PROSTHESIS IN THE MUSCULOSKELETAL SYSTEM OF HUMAN BODYes_ES