dc.descriptionUna empresa encargada de la gestión de una instalación de almacenamiento y llenado de Gases Licuados del Petróleo (GLP) se ha visto en la necesidad de certificar que su planta cumple las condiciones necesarias para garantizar la seguridad y salud de las personas, y el buen funcionamiento y mantenimiento de equipos en atmósferas explosivas (ATEX). Para ello se debe elaborar el documento de puesta en conformidad de zonas ATEX para dicha instalación, basándose en las normas de la API recommended practice 505 y la UNE-EN 60079. Dicho documento contiene el listado de sustancias, de fuentes de emisión, los planos de clasificación de áreas de peligrosidad y de la inspección de equipos que se encuentren dentro de dichas áreas. Con todo ello, se obtendrán unos resultados de cumplimiento de la conformidad o no de equipos e instalaciones y a partir de estos resultados se propondrán una serie de medidas correctoras que, una vez aplicadas, garantizarán la seguridad y salud de las personas, y el buen funcionamiento y mantenimiento de los equipos de la empresa. En este trabajo se describe el procedimiento llevado a cabo para la puesta en conformidad ATEX de la instalación mencionada y se presentan los principales resultados alcanzados.es_ES
dc.description.abstractA company responsible for the management of the Liquefied Petroleum Gases (LPG) storage and filling facility needs to certify that the plant meets the conditions necessary to ensure the safety and health for the workers and the proper operation and maintenance of equipment in explosive atmospheres (ATEX). For this reason, it is necessary to develop the document of setting in conformity of ATEX zones for this installation, based on the standards of the API recommended practice 505 and UNE-EN 60079-10. The document must include: list of substances, list of emission sources, hazardous area classification drawings and inspection of equipment located within these areas. From these results a conformity of the equipments and installations will be obtained and also a proposal of corrective measures that must be implemented for ensuring the safety and health of people, and the proper operation and maintenance of equipment. This work describes the procedure carried out to set in conformity ATEX zones in the mentioned installation and the main results obtained.es_ES
dc.language.isoeses_ES
dc.subjectGestión de Riesgos y Seguridades_ES
dc.titlePUESTA EN CONFORMIDAD ATEX DE UNA INSTALACIÓN DE ALMACENAMIENTO DE GASES LICUADOS DEL PETRÓLEOes_ES
dc.title.alternativeATEX CONFORMITY OF A FACILITY FOR LIQUEFIED PETROLEUM GASES (LPG) STORAGEes_ES