dc.contributor.authorCunha, Paulo
dc.contributor.authorMartins, Luís
dc.contributor.authorRodrigues De Seabra, Eurico Augusto
dc.contributor.authorTeixeira, José Carlos
dc.date.accessioned2017-10-23T08:14:22Z
dc.date.available2017-10-23T08:14:22Z
dc.date.issued2017
dc.identifier.isbn978-84-697-6121-2
dc.identifier.urihttp://dspace.aeipro.com/xmlui/handle/123456789/390
dc.descriptionO presente artigo descreve um sistema energético que permite gerir a energia calorífica da água da piscina, recorrendo a uma bomba de calor, e onde é utilizada a água da piscina e o interior da casa como fontes térmicas (fonte fria ou fonte quente), podendo o fluxo de calor trocar de sentido consoante as necessidades ao longo do ano. Assim, é demonstrado todo o fundamento teórico na modelação dos modelos térmicos de uma piscina e uma habitação, tendo sido os dois acoplados de modo a permitir a análise e discussão dos resultados do balanço energético e rendimentos obtidos através da comparação de diferentes situações, como por exemplo a utilização de uma cobertura opaca e/ou translúcida, criação de um modelo tanto para a estação de arrefecimento como para a de aquecimento. No que concerne aos resultados, é possível afirmar que o sistema é viável para ambas as estações de arrefecimento e aquecimento. No entanto, embora os resultados sejam concisos e devidamente fundamentados, é necessário validar esta análise com resultados experimentais, pois a precisão destes pode variar consoante as suposições consideradas. Além desta comparação, um estudo dos custos associados ao investimento inicial e manutenção para o consumidor final também é necessário.es_ES
dc.description.abstractThe present article describes an energy system based on a heat pump that can manage the heat energy of the water pool, where the pool water and the house are used as thermal sources (cold source or hot source). The heat flow direction can be changed according to the needs throughout the year. Thus, this work presents all the theoretical grounding for the thermal models of the pool and the house, both coupled to allow the analysis and discussion of the energy balance results and efficiency. Different situations were compared such as the use of an opaque and / or translucent cover, creating a model for both the cooling and heating seasons. Regarding the results, it can be said the system is viable for both the cooling and heating seasons. However, although the results are concise and reasonable, it is necessary to validate this analysis with experimental results because its precision can vary with assumptions made. Besides this comparison, it is also needed to study of the costs associated with the initial investment and maintenance for the consumer.es_ES
dc.language.isoeses_ES
dc.subjectIngeniería de Producto, Procesos y Diseño Industriales_ES
dc.titleOTIMIZAÇÃO DE UMA PISCINA NA SUA INTEGRAÇÃO ENERGÉTICO-AMBIENTAL COM O EDIFÍCIOes_ES
dc.title.alternativeOPTIMIZATION OF A SWIMMING POOL IN ITS ENERGY AND ENVIRONMENTAL INTEGRATION WITH THE BUILDINGes_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • CIDIP 2017 (Cádiz) [180]
    XXI Congreso Internacional de Dirección e Ingeniería de Proyectos (Cádiz, 2017)

Mostrar el registro sencillo del ítem