Mostrar el registro sencillo del ítem

dc.contributor.authorMacías Macías, José
dc.contributor.authorCruz Broche, Alberto
dc.contributor.authorBahamonde García, Manuel Ignacio
dc.date.accessioned2020-09-29T17:24:30Z
dc.date.available2020-09-29T17:24:30Z
dc.date.issued2020
dc.identifier.isbn978-84-09-21128-9
dc.identifier.urihttp://dspace.aeipro.com/xmlui/handle/123456789/2562
dc.descriptionSe ha evaluado el impacto que han tenido las modernizaciones de las instalaciones de riesgo en el Hospital Juan Ramón Jiménez de Huelva mediante la evolución del recuento microbiológico de Legionella spp en el agua circulante. Dado los altos valores que presentaban las analíticas y a pesar de efectuar choques térmicos e hipercloraciones con frecuencia, a partir de 2003 se optó por sustituir las redes de tuberías de agua fría y caliente originales de acero galvanizado por otras de materiales más resistentes desde el punto de vista químico como son el acero inoxidable 316 L y el polietileno reticulado, que además presentan menor tendencia a formar biocapas por sus propias características. Asimismo, se colocó un filtro en la entrada general de agua y otro en el punto de aporte a la instalación de agua caliente sanitaria. Se montaron nuevos depósitos de almacenamiento de agua caliente sanitaria y se comenta su disposición y materiales constructivos. Finalmente se sugiere que tipo de materiales pensamos que son más adecuados para minimizar el riesgo de proliferación de la bacteria. Tras la puesta en marcha de las medidas descritas, se ha observado una drástica disminución de la población de Legionella spp en el agua circulante.es_ES
dc.description.abstractThe impact of the modernization of the water systems was assessed through microbiological screening of the flowing water for Legionella Neumophila at Juan Ramón Jiménez Hospital in Huelva. As a consequence of the high number of this microorganism detected in previous periodic creenings, despite quite frequent chlorine-based and thermal disinfections, the decision was taken to substitute the original hot and cold water distribution pipes of galvanized steel for others with a higher spectrum of resistance to chemicals. Thus, 316L stainless steel and cross-linked polythene became the obvious choice, also considering the fact that they are less prone to biofilm formation. Similarly, water filters were placed at the hospital’s general water intake point and at the hot water inlet facilities. New hot water storage devices were assembled. In this paper, information is provided on their layout and the building materials used. Considerations are presented on the most appropriate kind of materials to minimize the risks of bacterial proliferation. The implementation of the measures described in this paper has resulted in a drastic decrease of Legionella Neumophila population in flowing water.es_ES
dc.language.isoeses_ES
dc.subject08-Gestión de Riesgos y Seguridades_ES
dc.titleEfecto del cambio de las tuberías de suministro de agua del Hospital Juan Ramón Jiménez en la proliferación de Legionellaes_ES
dc.title.alternativeEffect of the change of the water supply pipes of the Juan Ramón Jiménez Hospital in the proliferation of Legionellaes_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • CIDIP 2020 (Alcoy) [175]
    XXIV Congreso Internacional de Dirección e Ingeniería de Proyectos (Alcoy, 2020)

Mostrar el registro sencillo del ítem