dc.contributor.authorNieto Morote, Ana Mª
dc.contributor.authorVillarejo-Mañas, José Antonio
dc.contributor.authorRuz-Vila, Francisco de Asís
dc.contributor.authorde Jódar-Bonilla, Esther
dc.date.accessioned2020-09-29T17:20:47Z
dc.date.available2020-09-29T17:20:47Z
dc.date.issued2020
dc.identifier.isbn978-84-09-21128-9
dc.identifier.urihttp://dspace.aeipro.com/xmlui/handle/123456789/2531
dc.descriptionLas instalaciones fotovoltaicas están incrementando su potencia de forma muy rápida. En la actualidad, no es difícil encontrar instalaciones de decenas de megavatios y varias hectáreas de superficie, lo que complica la extracción de la energía generada y a la vez incrementa las pérdidas. Se plantea la posibilidad de incluir inversores para conexión a red que permita la conexión directa en media tensión. De entre las tensiones normalizadas se trabaja sobre una tensión de 6 kV como ya que llegar a tensiones superiores en las potencias utilizadas parece inalcanzable con los semiconductores actuales a un coste razonable. En el presente trabajo se analiza la viabilidad de la solución desde un punto de vista técnico-económico. En la medida que este cambio representa no solo un cambio en el inversor, sino también un cambio en la totalidad de la instalación se analizarán los costes asociados a sustituir aparamenta de baja tensión por la de media tensión, incluyendo conexiones, protecciones etc.es_ES
dc.description.abstractWith the development of renewable energy industry during recent years, the capacity of photovoltaic (PV) generation systems is increasing dramatically; nowadays, it is not difficult to find facilities of tens of megawatts and several hectares of surface, which complicates the collection of the generated energy and, as well as, increases the losses. Consequently, inverters should trend to reach the demands of high input voltage and wide input power ranges; then, the possibility of using MV grid-tied inverters is considered. Among the normalized voltages, a line voltage of 6 kV is considered since reaching higher voltages with limited input power up to 1MVA seems unaffordable with the semiconductor technologies available on the market at a reasonable cost. This paper analyzes the feasibility of the solution from both, technical and economic point of view. This change requires not only a change in inverter technology, but also an adaptation of the whole installation, the costs associated with replacing low voltage with medium voltage switchgear, including connections, protections, etc. will be analyzed.es_ES
dc.language.isoeses_ES
dc.subject05-Eficiencia Energética y Energías Renovableses_ES
dc.titleViabilidad técnico-económica para convertidores en MT para grandes instalaciones fotovoltaicases_ES
dc.title.alternativeTechnical and economic feasibility study on MV converters for large PV facilitieses_ES
dc.typeArticlees_ES