dc.descriptionEl Código Técnico de la Edificación (CTE) ha incorporado recientemente la microventilación como una alternativa viable e innovadora para la ventilación de viviendas. Para conseguir una aplicación eficiente y razonable, en el lado de la seguridad, según lo dispuesto en el CTE-DB-HS3, es preciso fijar unos criterios que, además de cumplir las normas vigentes, posibiliten un uso eficaz y seguro de funcionamiento y operatividad. Surgen dos alternativas muy diferenciadas. Por un lado, puede procederse a la fijación de unos parámetros de funcionamiento similares a los aireadores existentes. De esta forma, la microventilación sería como un aireador especial y estaría sometido a los mismos criterios. Habría que ajustar la realidad operativa y las particularidades de los ensayos para su adecuación. Por otra parte, la microventilación puede tratarse como una forma diferente de proceder a la ventilación de los edificios, permitiendo un funcionamiento continuo y fijo, durante un tiempo determinado, y otro diferente en función de lo que decida el usuario de la vivienda. En ambos casos, debe garantizarse la ventilación adecuada y si hay alternativas de funcionamiento elegir, en el lado de la seguridad aquella que produzca menos CO2, como norma esencial. La innovación es esencial, incluso en los aspectos operativos. Palabras clave: CTE; innovación; edificación; microventilación; criterioses_ES
dc.description.abstractThe Building Technical Code (BTC) has recently incorporated micro-ventilation as a viable and innovative alternative for house ventilation. To achieve an efficient and reasonable application, on the safety side, according to CTE-DBHS3, it is necessary to set some criteria which, as well as complying with current regulations, allow the effective and safe use of functioning and operation. There are two very different alternatives. On the one hand, operating parameters may be set that are similar to existing ventilation systems so that micro-ventilation will be as a special system and will be subjected to the same criteria. The operational reality and the details of the tests must be adjusted for its adaptation. On the other hand, micro-ventilation can be treated as a different way to produce ventilation in buildings, allowing continuous and fixed operation for a specific time and another, different one, depending on the decision of the user in the house. In both cases, suitable ventilation must be guaranteed and if there are operational alternatives to be chosen, the one that produces the least CO2 should be chosen to be on the safe side as a general rule. Innovation is essential, even in operational aspects. Keywords: BTC (CTE); innovation; building; micro-ventilation; criteriaes_ES
dc.language.isoeses_ES
dc.subjectIngeniería Civil, Urbanismo y Ordenación del Territorio. Construcción y Arquitecturaes_ES
dc.titleLA APLICACIÓN DEL CTE‐DB‐HS3 PARA LA VENTILACIÓN DE VIVIENDASes_ES
dc.title.alternativeLA APLICACIÓN DEL CTE‐DB‐HS3 PARA LA VENTILACIÓN DE VIVIENDASes_ES