dc.descriptionSegún el Código Técnico de la Edificación, España se divide en 12 zonas climáticas distintas. Los coeficientes de transmitancia térmica máxima permitidos en la construcción están limitados por esas zonas climáticas. Dichos valores son más reducidos en aquellos climas con inviernos más fríos. Para La Rioja existe la zona climática D2 para Logroño, D1 para localidades con un desnivel entre 200 y 400 metros con respecto a Logroño y E1 para localidades con un desnivel mayor de 400 metros. En este trabajo se propone determinar las zonas climáticas no sólo en función de la diferencia de altura, sino también de las temperaturas mínimas reales, adecuando las transmitancias a las mismas. Se trata de optimizar los sistemas de calefacción y climatización en las viviendas riojanas, con un proceso de innovación y mejora continua. La capacidad instalada para calefacción de hogares en diferentes localidades de La Rioja se compara de acuerdo con un mapa de temperatura hecho para toda La Rioja. En un primer caso, se calcula en función del CTE y en un segundo caso, en función de la temperatura mínima exterior. De esta forma se determinan las transmitancias límites óptimas. Esto permite un cálculo más realista de dichas instalaciones.es_ES
dc.description.abstractAccording to the Technical Building Code (TBC), Spain is divided into 12 different climate zones. The maximum thermal transmittance coefficients allowed in the construction are limited by those climate zones. These values are lower in those climates with colder winters. There are the following climate zones in La Rioja: Logroño D2, D1 for locations with a height between 200 and 400 meters with respect to Logroño and E1 for locations with a height greater than 400 meters. This study aims to determine the climate zones not only in terms of the height difference, but also the actual minimum temperatures, adjusting the transmittances to them. It is about optimizing heating and cooling systems in the Riojan homes, with a process of innovation and continuous improvement. Installed capacity for heating homes in different localities of La Rioja is compared according to a temperature map made for all La Rioja. In a first case, it is calculated based on the TBC; and in a second case, it is calculated based on the minimum outside temperature. The optimal limits transmittances will be determined in this way. This allows a more accurate calculation of these facilities.es_ES
dc.language.isoeses_ES
dc.subjectEficiencia Energética y Energías Renovableses_ES
dc.titleNUEVAS APORTACIONES DE DATOS CLIMÁTICOS AL CTE-DB-HE1 PARA SU APLICACIÓN EN LA COMUNIDAD AUTÓNOMA DE LA RIOJAes_ES
dc.title.alternativeNEW CLIMATE DATA CONTRIBUTIONS TO CTE-DB-HE1 FOR APPLICATION IN THE LA RIOJA AUTONOMOUS COMMUNITYes_ES