Mostrar el registro sencillo del ítem

dc.contributor.authorPiñero Vilela, José María
dc.contributor.authorCerezo Narváez, Alberto
dc.contributor.authorSánchez de la Flor, Francisco José
dc.contributor.authorOtero Mateo, Manuel
dc.contributor.authorPastor Fernández, Andrés
dc.date.accessioned2019-10-02T11:11:52Z
dc.date.available2019-10-02T11:11:52Z
dc.date.issued2019
dc.identifier.isbn978-84-09-13557-8
dc.identifier.urihttp://dspace.aeipro.com/xmlui/handle/123456789/2323
dc.descriptionEsta investigación trata de cuantificar la condena económica que han de soportar los usuarios finales de las edificaciones residenciales que, a pesar de estar construidas a mediados de la década pasada, en plena burbuja inmobiliaria, cumplen estrictamente la Norma Básica de la Edificación CT-79 sobre condiciones térmicas en los edificios, anterior a la entrada en vigor del Código Técnico de la Edificación en 2006 y sus modificaciones en materia de eficiencia energética de 2013, 2017 y 2018. Mediante la metodología de estudio de casos, se analiza la eficiencia energética de una vivienda unifamiliar adosada en el entorno costero de la provincia de Cádiz. A partir del análisis del comportamiento térmico de la vivienda en su estado actual, se proponen 2 casos alternativos (rehabilitación de vivienda existente y obra nueva adaptada) modificando las características constructivas de su envolvente, que pueden catalogarse como edificios de consumo casi nulo. A pesar de que se localiza en un clima no excesivamente severo ni en verano ni en invierno, en ambos casos se logran disminuir las demandas energéticas en torno al 60-70% en calefacción y 15-20% en refrigeración, con unos costes cuyo retorno puede amortizarse íntegramente en lo que les resta de ciclo de vida.es_ES
dc.description.abstractThis research seeks to quantify the economic condemnation that residential buildings’ end users have to endure, despite being built in the middle of the last decade, in full real estate bubble. They strictly comply with the Basic Building Standard CT-79 on thermal conditions of buildings, prior to the entry into force of the Technical Building Code in 2006 and its modifications related to energy efficiency in 2013, 2017 and 2018. Using the case study methodology, the energy efficiency of a detached single-family house in the coastal area of the province of Cadiz is analysed. Based on the analysis of the thermal behaviour of the house in its current state, 2 alternative cases are proposed (rehabilitation of the existing house and an adapted new one) modifying the constructive characteristics of its envelope, which can be catalogued as a nearly zero-energy building. Despite the fact that it is located in a climate that is not excessively severe in either summer or winter, in both cases energy demands are reduced by around 60-70% in heating and 15-20% in cooling, with costs whose return can be fully depreciated in its remaining life cycle.es_ES
dc.language.isoeses_ES
dc.subjectEficiencia Energética y Energías Renovableses_ES
dc.titleEficiencia energética de las viviendas de la burbuja inmobiliaria. Estudio de casoes_ES
dc.title.alternativeEnergy efficiency of housing in the Spanish real estate bubble. A case studyes_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • CIDIP 2019 (Málaga) [169]
    XXIII Congreso Internacional de Dirección e Ingeniería de Proyectos (Málaga, 2019)

Mostrar el registro sencillo del ítem