dc.descriptionEl sistema de ventilación en viviendas puede ser mecánico o híbrido, limitándose el uso de ventilación natural como sistema complementario. El extractor mecánico debe estar en funcionamiento continuo durante todo el día, mientras que el extractor híbrido sólo entra en funcionamiento cuando no se den las condiciones para que exista tiro natural. En cualquier caso, los requisitos de diseño para el sistema híbrido serán similares a los del sistema mecánico, además de cumplir una serie de requisitos especiales debido a la necesidad de que pueda realizarse la ventilación de modo natural. Básicamente se busca reducir las causas de pérdidas de presión y aumentar el tiro en todo lo posible. Estas exigencias evidentemente no son necesarias cuando se realiza la extracción de modo mecánico. La ventilación híbrida supone la necesidad de incluir más elementos y disponer de una instalación más grande y compleja. Este sistema requiere elementos de medición y control para el funcionamiento de los aspiradores como ventilación mecánica o como ventilación natural, cuando se pueda. El sistema híbrido es más caro, aunque ahorra energía. No obstante, el promotor decide el sistema elegido, si bien el beneficiario del ahorro energético será en comprador de la vivienda. Palabras clave: CTE; ventilación mecánica; ventilación híbrida; ahorro energéticoes_ES
dc.description.abstractA house ventilation system can be mechanical or hybrid with the use of natural ventilation being limited to a complementary system. The mechanical extractor must operate continuously throughout the day while the hybrid extractor only starts to operate when the conditions for natural ventilation are not present. In any case, the design requirements for the hybrid system will be similar to those of the mechanical system as well as complying with a series of special requirements due to the need to provide natural ventilation. Basically, it attempts to reduce the causes of pressure losses and increase the flow as far as possible. Evidently, these requirements are not necessary when extraction is mechanical. The hybrid ventilation implies the need to include more elements and for a larger and more complex installation. This system requires measurement and control elements for the units to operate as mechanical ventilation or as natural ventilation when possible. The hybrid system is more expensive although it saves energy. Nevertheless, the developer decides on the chosen system although the beneficiary of the energy saving will be the house purchaser. Keywords: BTC (CTE); mechanical ventilation; hybrid ventilation; energy savinges_ES
dc.language.isoeses_ES
dc.subjectIngeniería Civil, Urbanismo y Ordenación del Territorio. Construcción y Arquitecturaes_ES
dc.titleLA VENTILACIÓN DE LAS VIVIENDAS EN EL VIGENTE CÓDIGO TÉCNICO DE LA EDIFICACIÓN (CTE): SISTEMAS MECÁNICOS E HÍBRIDOSes_ES
dc.title.alternativeLA VENTILACIÓN DE LAS VIVIENDAS EN EL VIGENTE CÓDIGO TÉCNICO DE LA EDIFICACIÓN (CTE): SISTEMAS MECÁNICOS E HÍBRIDOSes_ES