dc.descriptionLa aplicación del actual Documento Básico de Ahorro de Energía del Código Técnico de la Edificación (CTE-DB-HE) asegura un gran ahorro en el consumo de energía primaria no renovable y una gran reducción de las emisiones de CO2 de los edificios que se rehabiliten. El actual CTE-DB-HE exige a los edificios educativos rehabilitados una limitación de la demanda energética, una eficiencia energética de las instalaciones de iluminación y una contribución solar mínima de agua caliente sanitaria (ACS). Mientras que, a los edificios educativos de nueva construcción les exige, además de todo lo anterior, una mayor limitación de la demanda energética y una limitación del consumo energético. En este trabajo se estudian dos soluciones de rehabilitación energética para un instituto de educación secundaria construido en 1990 y ubicado en Logroño (La Rioja): una para que cumpla como edificio rehabilitado y otra para que cumpla como edificio nuevo. En ambas se emplean sistemas de aislamiento térmico exterior, se sustituye la caldera existente de gasóleo C para calefacción y ACS por una de condensación de gas natural, se mejoran las instalaciones de iluminación y se incorpora un sistema de apoyo solar para cubrir parte de las necesidades de ACS.es_ES
dc.description.abstractApplying the current Basic Document of Energy Saving of the Technical Building Code (CTE-DB-HE) ensures significant savings in terms of the non-renewable primary energy consumption and a significant reduction in the CO2 emissions of rehabilitated buildings. The current CTE-DB-HE requires that rehabilitated educational buildings demand limited amounts of energy, have energy-efficient lighting installed, and use a certain amount of solar energy for domestic hot water (DHW). Newly constructed educational buildings must comply with even stricter limits on energy demand and consumption. In this paper, two energy rehabilitation solutions are studied for a secondary school institute built in 1990 and located in Logroño (La Rioja), one for a rehabilitated building and the other for a new building. In both, external thermal insulation composite systems are used, the existing heating oil boiler for heating and DHW is replaced by a natural gas condensing boiler, the lighting installation is improved, and a solar support system is incorporated to cover part of the DHW needs.es_ES
dc.language.isoeses_ES
dc.subjectEficiencia Energética y Energías Renovableses_ES
dc.titlePOSIBILIDADES DE REHABILITACIÓN ENERGÉTICA DE UN INSTITUTO DE EDUCACIÓN SECUNDARIA CONSTRUIDO EN 1990 APLICANDO EL ACTUAL CTE-DB-HEes_ES
dc.title.alternativePOSSIBILITIES FOR THE ENERGY REHABILITATION OF A SECONDARY EDUCATION INSTITUTE BUILT IN 1990 BASED ON THE CURRENT CTE-DB-HEes_ES
dc.typeArticlees_ES