Mostrar el registro sencillo del ítem

dc.contributor.authorFerrer Gisbert, Pablo S.
dc.contributor.authorVivancos Bono, José Luis
dc.contributor.authorAparicio Fernández, Carolina Sabina
dc.date.accessioned2015-05-25T10:25:57Z
dc.date.available2015-05-25T10:25:57Z
dc.date.issued2014
dc.identifier.isbn978-84-617-2742-1
dc.identifier.urihttp://dspace.aeipro.com/xmlui/handle/123456789/150
dc.descriptionLas ganancias y pérdidas de calor a través de las fachadas tienen una influencia significativa en el consumo de climatización de los edificios. Además, existe una tendencia reciente entre algunos arquitectos a considerar las fachadas como sofisticadas membranas que deberían ser diseñadas cuidadosamente. Aunque el uso de fachadas de doble piel (cerramientos de cristal separados por una cavidad) en el sector de la construcción y sus beneficios térmicos ha sido ampliamente estudiado durante los últimos treinta años, la fachada ventilada o “pantalla de lluvia” (caracterizada por una pantalla exterior opaca con aberturas) ha recibido menos atención y existen todavía pocos estudios sobre su comportamiento energético. En esta ponencia revisamos las últimas contribuciones al comportamiento térmico de las fachadas ventiladas incluyendo los estudios más recientes respecto al uso de la ventilación natural en edificios como sistema para reducir la demanda energética. Palabras clave: Fachadas ventiladas; ventilación natural; eficiencia energética en edificioses_ES
dc.description.abstractLosses and heat gains through the facades have a significant influence on annual consumption of heating and cooling of buildings. Moreover, there is a recent trend among some architects considering facades as sophisticated membranes that should be carefully designed. Although the use of double-skin façades (glass skins separated by a cavity) in the construction sector and their thermal benefits have been widely studied quantitatively over the last 30 years, the rainscreen ventilated façade (characterized by an open joint opaque external skin) has received less attention and there are still few studies that focus on their energy performance. In this article we review the latest contributions to the thermal behavior of ventilated facades including the most recent studies on the use of natural ventilation in buildings as an alternative system to reduce energy demand. Keywords: Ventilated facades; natural ventilation; energy efficiency in buildingses_ES
dc.language.isoeses_ES
dc.subjectEficiencia Energética y Energías Renovableses_ES
dc.titleCOMPORTAMIENTO TÉRMICO DE LAS FACHADAS VENTILADAS EN EDIFICACIÓNes_ES
dc.title.alternativeTHERMAL BEHAVIOR OF VENTILATED FACADES IN BUILDINGSes_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • CIDIP 2014 (Alcañiz) [184]
    XVIII Congreso Internacional de Dirección e Ingeniería de Proyectos (Alcañiz, 2014)

Mostrar el registro sencillo del ítem