Mostrar el registro sencillo del ítem

dc.contributor.authorSánchez Carratalá, Carlos R.
dc.date.accessioned2015-05-25T10:25:53Z
dc.date.available2015-05-25T10:25:53Z
dc.date.issued2014
dc.identifier.isbn978-84-617-2742-1
dc.identifier.urihttp://dspace.aeipro.com/xmlui/handle/123456789/139
dc.descriptionLa mayor parte de los huertos solares fotovoltaicos instalados directamente sobre el terreno tienen paneles con orientación fija, montados sobre estructuras soporte formadas por pórticos simples de uno o dos pilares. Entre las distintas posibilidades de cimentación de dichas estructuras, una de las más habituales es el empleo de pilotes hincados, generalmente de longitud pequeña. Las mesas en las que se agrupan los paneles se comportan en la práctica como marquesinas de pequeña altura a una agua, normalmente sin obstrucción en la parte inferior. El empuje del viento que actúa sobre las mesas, con sus componentes perpendicular (presión o succión) y paralela (fricción) a las superficies superior e inferior del panel, da lugar a una fuerza horizontal o lateral que debe ser absorbida por la cimentación. En esta ponencia se revisan los métodos más habituales para la determinación de la resistencia frente a carga lateral de pilotes hincados en suelos granulares. Asimismo, se comparan los resultados obtenidos con varios métodos existentes, proponiendo un nuevo método de cálculo basado en una distribución de presiones del terreno más acorde con el movimiento del pilote en rotura, lo que permite obtener un mejor ajuste de los ensayos en modelo y en prototipo. Palabras clave: energía solar fotovoltaica; parques solares; cargas laterales; cimentación; pilotes hincados; suelos granulareses_ES
dc.description.abstractMost photovoltaic solar farms directly installed on the ground have panels with fixed orientation, which are mounted on support structures formed by simple frames with one or two columns. Among the different possibilities for the foundation of those structures, one of the most common is the use of driven piles, usually of short length. The tables in which the panels are grouped behave in practice like mono-pitched marquees of small height, typically without obstruction in the lower part. Wind load acting on the tables, with components both perpendicular (pressure or suction) and parallel (friction) to the upper and lower surfaces of the panel, results in a horizontal or lateral force that has to be absorbed by the foundation. In this paper the most common methods for determining the lateral load resistance of driven piles in cohesionless soils are reviewed. Also, the results obtained with several existing methods are compared, proposing a new method based on a ground pressure distribution more consistent with the ultimate movement of the pile, which allows to obtain a better fit of model and prototype tests. Keywords: solar photovoltaics; solar farms; lateral loads; foundation; driven piles; cohesionless soilses_ES
dc.language.isoeses_ES
dc.subjectEficiencia Energética y Energías Renovableses_ES
dc.titleCOMPROBACIÓN DE LA RESISTENCIA FRENTE A CARGA LATERAL DE PILOTES HINCADOS EN SUELOS GRANULARES PARA CIMENTACIONES DE HUERTOS SOLARES FOTOVOLTAICOSes_ES
dc.title.alternativeVERIFICATION OF LATERAL LOAD RESISTANCE OF DRIVEN PILES IN COHESIONLESS SOILS FOR FOUNDATIONS OF PHOTOVOLTAIC SOLAR FARMSes_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • CIDIP 2014 (Alcañiz) [184]
    XVIII Congreso Internacional de Dirección e Ingeniería de Proyectos (Alcañiz, 2014)

Mostrar el registro sencillo del ítem